Glass process

Since the amendment to the German Technical Instructions on Air Quality Control the waste gases from glass-kilns need to be precipitated. Dust collecting is done at high temperatures in the filter. In some cases spray absorption is also used for contaminant gas purification behind glass troughs.

fc_glas_en Filter for glass-kiln
1 NaOH tank 2 Water 3 Hot gas from the glass trough 4 Quench reactor
5 Filter for glass-kiln 6 Chimney 7 Dosing pump 8 Quench pump
9 Transport container 10 Induced draft        
Filter title
typical design data Unit of measure Filter
Gas volume m³/h 38,000
Gas temperature °C 180 - 200
Type of dust   Sodium sulphate, soda, borax, quartz
Residual dust content mg/m³ < 10
Raw gas dust content g/m³ 10 - 25
Cleaning   offline
Filter medium   Polyimide
Explosion protected design   not necessary
Sorbent   Sodium hydroxide